Personalized Practice Fit Comparison

Which CT fits the practice you are building?

Build a picture of the practice by selecting every service, clinical use, and operating priority that applies. The tool weights the full combination—not just one answer—to compare each system as a fit for that specific hospital.

How to read the score: Checked clinical uses receive the strongest weight, operational priorities refine the ranking, and fixed constraints can rule a system down. Every result explains why it ranked and what could change the recommendation.
01

Tell us what the CT program must support

Select all that apply. Each checked answer contributes to the fit score, while room, volume, and investment remain fixed constraints.

1Which services describe your practice today—or the program you are building?

Select every relevant service. These choices establish the base weighting for the comparison.

2Which clinical uses must the CT support?

Select every anatomy or use case that will materially affect the purchase. These receive the strongest added weight.

3What operating priorities matter to your team?

Choose as many as needed. These refine the ranking without overpowering the clinical use cases.

4Available room
5Expected CT volume
6Investment posture
7How do you expect images to be interpreted?

Select all that apply. Some hospitals use more than one reading pathway.

Weighting approach: practice selections create the baseline; clinical uses add high weight; operating priorities add moderate weight; room, volume, and advanced cardiac needs can also apply hard constraints.
Personalized comparison

Your leading practice-fit options

02

Browse the scored comparison set

Explore 33 systems with the same clinical and operating criteria. The ten reviewed systems drive the leading matches; expanded model-family benchmarks are clearly identified as preliminary until their ratings are reviewed.

Select up to four systems to compare.

03

Compare selected systems

Choose up to four scored systems. Ratings are shown beside the current practice-fit score, key tradeoffs, and facility-planning notes.

No systems selected yet. Use Add to comparison on any scored system.
04

Explore the broader CT market

Search a sanitized snapshot of the CT Systems Library. These entries broaden the conversation; they are not automatically scored or recommended until the model family has been reviewed against the same criteria.

Catalog snapshot reviewed August 21, 2026.

05

Facility planning comparison

Scanner footprint is not room size. Use this table to screen the project, then require a current, configuration-specific site drawing before construction or purchase.

Planning reference—not a construction specification. Power, shielding, HVAC, floor loading, table selection and delivery route can change with configuration, jurisdiction and building conditions.
SystemPlanning roomPowerShieldingDelivery / rigging pathOther site needs
NewTom 7G VET10 × 15 ft early planning baseline; the current manufacturer site drawing controls240 VAC, 35 A; dedicated grounded circuitPhysicist-designed shielding plan requiredApprox. 80.7-in system width; engineered delivery path and final rig plan requiredLevel floor rated at least 61 lb/ft²; system weight about 2,325 lb
MyVet CT Plus11 × 9 × 7.3 ft minimum; at least 18 in behind gantry220–240 VAC, 25 A, single phase; 5.5 kVAPhysicist plan required; external workstation/viewing window recommended36-in minimum finished door widthLevel non-carpet floor rated 102 lb/ft²; 64–75°F with active temperature control
MyVet CT i3D11 × 9 × 7.3 ft minimum; at least 18 in behind gantry120 VAC, 25 A or 240 VAC, 20 A; single phasePhysicist plan required; external workstation/viewing window recommended36-in minimum finished door widthLevel non-carpet floor rated 102 lb/ft²; system weight about 1,321 lb
Xoran VetCATNo traditional CT suite often needed; unit is 32 × 47 in and 60/67 in highStandard 120 V or 230 V outlet; 20 A maximum draw at 120 VSelf-shielded design; confirm placement with local physicist/AHJFits standard doorways; mobile 4-wheel platform472-lb unit; lockable level position and safe anesthesia workflow
VIMAGO GT30Formal site plan required; working envelope about 7.6 × 4.9 × 5.4 ft before clearancesPublished international configuration: 230 V, 20 A; confirm U.S. configurationSite-specific physicist review requiredTransport width about 29 in; manufacturer states it passes a standard doorApprox. 926 lb; confirm operating clearances, fluoroscopy use and floor loading
GE Revolution ACT 3215.4 × 11.9 ft suggested with PDU in room; 15.4 × 10.5 ft with PDU outside; 14.4 × 8.1 ft short-footprint minimum200–480 VAC; 30 kVA standard or 40 kVA option; dedicated feeder/transformer planningConventional dedicated CT room with physicist-approved planFormal route survey; heavy components must not be tilted 10° or more; dock, liftgate or riggers may be neededMinimum layout can limit cradle travel and service flexibility; HVAC and floor review required
GE BrightSpeed 1613 × 20 ft 8 in recommended; 12 ft 10 in × 19 ft 3 in typical; limited-access minimum about 11 × 18 ft200–480 VAC, 3-phase; 90 kVAQualified-physicist shielding plan required42 × 82-in unobstructed opening; 8-ft corridor helpful; gantry roughly 4,849 lbDedicated HVAC, level structural floor and full service clearances
GE LightSpeed VCT 6425 ft 6 in × 14 ft 6 in suggested; 20 × 13 ft 6 in typical with VT1700 table; 19 ft 2 in × 11 ft 8 in minimum380–480 VAC, 3-phase; 150 kVAQualified-physicist shielding plan required42 × 82-in unobstructed opening; 8-ft corridor helpful; engineered route and floor protectionSubstantial HVAC/cooling, structural, equipment-room and service-clearance planning
Canon Aquilion 64 familyAbout 14 × 20 ft plus operator/equipment area in the reviewed planning reference208 V/200 A or 480 V/100 A, 3-phase; exact configuration controlsLegacy reference used 1/32-in lead to 7 ft; final design must come from a physicistFormal turning study required; example rig plan uses a 4–6 ft clear opening depending on corridor widthApprox. 4,849 lb; verify HVAC, floor, table, tube and exact Aquilion generation
Siemens SOMATOM Definition AS 64Minimum scanner room about 18 m² / 194 ft²; full suite requires separate control/equipment planning400 V ±10%, 3-phase; 86.5 kVA connection, with configuration-dependent peaks up to 125–140 kVASite-specific radiation calculation and plan requiredAbout 49-in final door clearance when bed entrance is required; gantry transport weight about 5,267 lbAir- or water-cooling plan, structural/vibration review and 7 ft 6.6 in minimum room height

Values summarize the reviewed manufacturer or provider planning materials. Refurbished CT requirements are serial-number, table, tube, cooling and configuration specific. Local code and the approved site drawing always control.

06

What the score does—and does not—mean

This comparison combines published product information with Chris Weaver's experience and stated weighting of veterinary workflow priorities.

Fit is contextual

The same scanner can be an excellent dental choice and a poor advanced-cardiac choice. A lower score here is not a declaration that a system is “bad.”

Hard constraints matter

Space, advanced cardiac work, high throughput, and must-have clinical functions can reduce a score even when the system performs well elsewhere.

Final proof is still required

Shortlisted systems should survive matched-case review, a current site plan, five-year cost comparison, and written service terms.

This tool is independently maintained and is not a manufacturer specification, diagnosis, construction drawing, price quote, or guarantee. Scores are advisory and may change as the weighting model and source evidence are refined. Facility values are preliminary screening references only; require a current approved site plan before construction or purchase.